===== Calculator of maximum power loss from thermal resistance =====
|< 100% 10% 90% >|
| {{/calculator/icon_calc.png?60&nolink}} | //[[user/Stan Zurek]], Calculator of maximum power loss from thermal resistance, Encyclopedia Magnetica//, \\ https://www.e-magnetica.pl/doku.php/calculator/maximum_loss_from_thermal_resistance, {accessed: @YEAR@-@MONTH@-@DAY@} |
If thermal resistance is known for given device and cooling conditions then a maximum loss dissipation can be calculated from the following equation.
|< 100% 25% 60% 5% >|
^ Maximum power loss from thermal resistance ^^^
| //Source: [1] [[https://isbnsearch.org/isbn/9781118717790|Marian K. Kazimierczuk, High-Frequency Magnetic Components, Second edition, John Wiley & Sons, Chichester, 2014, ISBN 9781118717790]]// |||
| //a direct consequence of: \\ [1], eq. (2.276), p. 151// | $$ P_{max} = \frac{T_{max} - T_{ambient}}{R_{th}} $$ | (W) |
\\
//Note: the maximum temperature must be greater than the ambient value.//
↑