calculator:maximum_loss_from_thermal_resistance
This is an old revision of the document!
Calculator of maximum power loss from thermal resistance
Stan Zurek, Calculator of maximum power loss from thermal resistance, Encyclopedia Magnetica, http://e-magnetica.pl/doku.php/calculator/maximum_loss_from_thermal_resistance, {accessed: 2025-03-14} |
If thermal resistance is known for given device and cooling conditions then a maximum loss dissipation can be calculated from the following equation.
$$ P_{max} = \frac{T_{max} - T_{ambient}}{R_{th}} $$ | (W) |
Note: the maximum temperature must be greater than the ambient value.