file:initial_permeability_cgo_electrical_steel_magnetica_png
Measured values of relative amplitude permeability μr for a typical conventional grain-oriented electrical steel.
At sufficiently low excitation the material operates in the initial permeability region, in which the permeability is constant and the process is mostly reversible, because the domain walls remain pinned.
The data was measured by S. Zurek.
initial_permeability_cgo_electrical_steel_magnetica.png
You are permitted and indeed encouraged to use this image freely, for any legal purpose including commercial, and with any modifications (the permission is hereby given, so there is no need to ask for it explicitly again), but you MUST always give the following credits:
S. Zurek, Encyclopedia Magnetica, CC-BY-4.0
We would appreciate if you let us know of any use: info@e-magnetica.pl